<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="rss.xsl"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Baxter Healthcare — recent CVEs</title>
    <link>https://vulnogram.org/</link>
    <atom:link href="https://vulnogram.org/rss/baxter" rel="self" type="application/rss+xml"/>
    <description>Most recent CVEs assigned by Baxter Healthcare (baxter).</description>
    <image>
      <url>https://vulnogram.org/seaview/icons/baxter.png</url>
      <title>Baxter Healthcare — recent CVEs</title>
      <link>https://vulnogram.org/</link>
    </image>
    <lastBuildDate>Wed, 21 Oct 2026 07:00:07 GMT</lastBuildDate>
    <item>
      <title>CVE-2022-26389 · 7.7 HIGH — Improper Access Control Vulnerability in ELI Electrocardiograph Devices</title>
      <link>https://vulnogram.org/CVE-2022-26389</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26389</guid>
      <description>An improper access control vulnerability may allow privilege escalation.This issue affects: * ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; * ELI 250c/BU…</description>
      <category>High</category>
      <pubDate>Fri, 07 Feb 2025 17:07:27 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-26388 · 6.4 MEDIUM — Use of Hard-Coded Password Vulnerability in ELI Electrocardiograph Devices</title>
      <link>https://vulnogram.org/CVE-2022-26388</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26388</guid>
      <description>A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; ELI 250c/BUR 250…</description>
      <category>Medium</category>
      <pubDate>Fri, 07 Feb 2025 17:06:30 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48967 · 10 CRITICAL 🌩️ — Life2000 ventilator and Service PC lack sufficient audit logging capabilities</title>
      <link>https://vulnogram.org/CVE-2024-48967</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48967</guid>
      <description>The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, m…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 14 Nov 2024 21:40:44 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48966 · 10 CRITICAL 🌩️ — Life2000 service tools for test and calibration do not support user authentication</title>
      <link>https://vulnogram.org/CVE-2024-48966</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48966</guid>
      <description>The software tools used by service personnel to test &amp; calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or m…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 14 Nov 2024 21:38:11 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48970 · 9.3 CRITICAL — Life2000 Ventilator microcontroller lacks memory protection</title>
      <link>https://vulnogram.org/CVE-2024-48970</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48970</guid>
      <description>The ventilator&apos;s microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause un…</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 21:31:14 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48974 · 9.3 CRITICAL — Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates</title>
      <link>https://vulnogram.org/CVE-2024-48974</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48974</guid>
      <description>The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device&apos;s configuration settings and/or compromise device functionality by pushing…</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 21:27:10 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48973 · 9.3 CRITICAL — Debug port on Life2000 Ventilator serial interface is enabled by default</title>
      <link>https://vulnogram.org/CVE-2024-48973</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48973</guid>
      <description>The debug port on the ventilator&apos;s serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or h…</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 21:24:14 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-48971 · 9.3 CRITICAL — Clinician Password and Serial Number Clinician Password are hard-coded in Life2000 Ventilator</title>
      <link>https://vulnogram.org/CVE-2024-48971</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-48971</guid>
      <description>The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinic…</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 21:13:36 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-9832 · 9.3 CRITICAL — No limit on failed login attempts with Clinician Password or Serial Number Clinician Password on Life2000 Ventilator</title>
      <link>https://vulnogram.org/CVE-2024-9832</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-9832</guid>
      <description>There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make change…</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 21:03:16 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-9834 · 9.3 CRITICAL — Improper data protection on Life2000 ventilator serial interface</title>
      <link>https://vulnogram.org/CVE-2024-9834</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-9834</guid>
      <description>Improper data protection on the ventilator&apos;s serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.</description>
      <category>Critical</category>
      <pubDate>Thu, 14 Nov 2024 20:57:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-6796 · 8.2 HIGH 🌩️ — Vulnerability in Baxter Connex Health Portal</title>
      <link>https://vulnogram.org/CVE-2024-6796</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-6796</guid>
      <description>In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal&apos;s database and/or modify content.</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 09 Sep 2024 19:28:30 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-6795 · 10 CRITICAL 🌩️ — Vulnerability in Baxter Connex Health Portal</title>
      <link>https://vulnogram.org/CVE-2024-6795</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-6795</guid>
      <description>In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal&apos;s database. An attacker could have submitted a crafted payload…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 09 Sep 2024 19:24:01 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-5176 · 9.4 CRITICAL 🌩️ — Vulnerability in Welch Allyn Configuration Tool Software</title>
      <link>https://vulnogram.org/CVE-2024-5176</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-5176</guid>
      <description>Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Fri, 31 May 2024 17:26:05 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-1275 · 9.1 CRITICAL 🌩️ — Vulnerability in Baxter Welch Allyn Connex Spot Monitor</title>
      <link>https://vulnogram.org/CVE-2024-1275</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-1275</guid>
      <description>Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Fri, 31 May 2024 17:23:19 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-26393 · 5 MEDIUM — Format String vulnerability</title>
      <link>https://vulnogram.org/CVE-2022-26393</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26393</guid>
      <description>The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM.</description>
      <category>Medium</category>
      <pubDate>Fri, 09 Sep 2022 14:40:06 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-26390 · 4.2 MEDIUM — Unencrypted internal storage of security credentials</title>
      <link>https://vulnogram.org/CVE-2022-26390</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26390</guid>
      <description>The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypted form. An attacker with physical access to a device that hasn&apos;t had all data and settings…</description>
      <category>Medium</category>
      <pubDate>Fri, 09 Sep 2022 14:40:06 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-26392 · 3.1 LOW — Format String vulnerability</title>
      <link>https://vulnogram.org/CVE-2022-26392</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26392</guid>
      <description>The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sen…</description>
      <category>Low</category>
      <pubDate>Fri, 09 Sep 2022 14:40:06 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-26394 · 5.5 MEDIUM — Unauthenticated network reconfiguration via TCP/UDP</title>
      <link>https://vulnogram.org/CVE-2022-26394</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-26394</guid>
      <description>The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack that modifies parameters making the network connection fail.</description>
      <category>Medium</category>
      <pubDate>Fri, 09 Sep 2022 14:40:05 GMT</pubDate>
    </item>
  </channel>
</rss>