<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="rss.xsl"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Becton, Dickinson and Company (BD) — recent CVEs</title>
    <link>https://vulnogram.org/</link>
    <atom:link href="https://vulnogram.org/rss/bd" rel="self" type="application/rss+xml"/>
    <description>Most recent CVEs assigned by Becton, Dickinson and Company (BD) (bd).</description>
    <image>
      <url>https://vulnogram.org/seaview/icons/bd.png</url>
      <title>Becton, Dickinson and Company (BD) — recent CVEs</title>
      <link>https://vulnogram.org/</link>
    </image>
    <lastBuildDate>Wed, 21 Oct 2026 07:00:07 GMT</lastBuildDate>
    <item>
      <title>CVE-2024-10476 · 8 HIGH</title>
      <link>https://vulnogram.org/CVE-2024-10476</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-10476</guid>
      <description>Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally ide…</description>
      <category>High</category>
      <pubDate>Tue, 17 Dec 2024 15:16:44 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29066 · 3.2 LOW — Incorrect User Management</title>
      <link>https://vulnogram.org/CVE-2023-29066</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29066</guid>
      <description>The FACSChorus software does not properly assign data access privileges for operating system user accounts. A non-administrative OS account can modify information stored in the local application data folders.</description>
      <category>Low</category>
      <pubDate>Tue, 28 Nov 2023 20:36:13 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29065 · 4.1 MEDIUM — Overly Permissive Access Policy</title>
      <link>https://vulnogram.org/CVE-2023-29065</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29065</guid>
      <description>The FACSChorus software database can be accessed directly with the privileges of the currently logged-in user. A threat actor with physical access could potentially gain credentials, which could be used to alter or destroy data stored in the database…</description>
      <category>Medium</category>
      <pubDate>Tue, 28 Nov 2023 20:35:59 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29064 · 4.1 MEDIUM — Hardcoded Secrets</title>
      <link>https://vulnogram.org/CVE-2023-29064</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29064</guid>
      <description>The FACSChorus software contains sensitive information stored in plaintext. A threat actor could gain hardcoded secrets used by the application, which include tokens and passwords for administrative accounts.</description>
      <category>Medium</category>
      <pubDate>Tue, 28 Nov 2023 20:35:30 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29063 · 2.4 LOW — Lack of DMA Access Protections</title>
      <link>https://vulnogram.org/CVE-2023-29063</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29063</guid>
      <description>The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker…</description>
      <category>Low</category>
      <pubDate>Tue, 28 Nov 2023 20:34:59 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29062 · 3.8 LOW — Unsecure Identity Verification</title>
      <link>https://vulnogram.org/CVE-2023-29062</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29062</guid>
      <description>The Operating System hosting the FACSChorus application is configured to allow transmission of hashed user credentials upon user action without adequately validating the identity of the requested resource. This is possible through the use of LLMNR, M…</description>
      <category>Low</category>
      <pubDate>Tue, 28 Nov 2023 20:34:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29061 · 5.2 MEDIUM — Lack of Adequate BIOS Authentication</title>
      <link>https://vulnogram.org/CVE-2023-29061</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29061</guid>
      <description>There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authenticati…</description>
      <category>Medium</category>
      <pubDate>Tue, 28 Nov 2023 20:33:44 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-29060 · 5.4 MEDIUM — Lack of USB Whitelisting</title>
      <link>https://vulnogram.org/CVE-2023-29060</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-29060</guid>
      <description>The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to the workstation could gain access to system information and potentially exfiltrate data.</description>
      <category>Medium</category>
      <pubDate>Tue, 28 Nov 2023 20:07:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30565 · 3.5 LOW — CQI Data Sniffing</title>
      <link>https://vulnogram.org/CVE-2023-30565</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30565</guid>
      <description>An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker.</description>
      <category>Low</category>
      <pubDate>Thu, 13 Jul 2023 19:06:18 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30564 · 6.9 MEDIUM — Stored Cross-Site Scripting on Device Import Functionality</title>
      <link>https://vulnogram.org/CVE-2023-30564</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30564</guid>
      <description>Alaris Systems Manager does not perform input validation during the Device Import Function.</description>
      <category>Medium</category>
      <pubDate>Thu, 13 Jul 2023 19:06:02 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30563 · 8.2 HIGH 🌩️ — Stored Cross-Site Scripting on User Import Functionality</title>
      <link>https://vulnogram.org/CVE-2023-30563</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30563</guid>
      <description>A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session.</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 13 Jul 2023 19:04:43 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30562 · 6.7 MEDIUM — Lack of Dataset Integrity Checking</title>
      <link>https://vulnogram.org/CVE-2023-30562</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30562</guid>
      <description>A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs.</description>
      <category>Medium</category>
      <pubDate>Thu, 13 Jul 2023 19:03:32 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30561 · 6.1 MEDIUM — Lack of Cryptographic Security of IUI Bus</title>
      <link>https://vulnogram.org/CVE-2023-30561</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30561</guid>
      <description>The data flowing between the PCU and its modules is insecure. A threat actor with physical access could potentially read or modify data by attaching a specially crafted device while an infusion is running.</description>
      <category>Medium</category>
      <pubDate>Thu, 13 Jul 2023 19:03:17 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30560 · 6.8 MEDIUM — PCU Configuration Lacks Authentication</title>
      <link>https://vulnogram.org/CVE-2023-30560</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30560</guid>
      <description>The configuration from the PCU can be modified without authentication using physical connection to the PCU.</description>
      <category>Medium</category>
      <pubDate>Thu, 13 Jul 2023 18:53:49 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-30559 · 5.2 MEDIUM — Wireless Card Firmware Improperly Signed</title>
      <link>https://vulnogram.org/CVE-2023-30559</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-30559</guid>
      <description>The firmware update package for the wireless card is not properly signed and can be modified.</description>
      <category>Medium</category>
      <pubDate>Thu, 13 Jul 2023 17:50:13 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-47376 · 7.3 HIGH</title>
      <link>https://vulnogram.org/CVE-2022-47376</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-47376</guid>
      <description>The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the installation. No patient health data is stored in the database, although some site installations may choose to store personal data.</description>
      <category>High</category>
      <pubDate>Tue, 13 Jun 2023 00:00:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-43557 · 5.3 MEDIUM — BD BodyGuard™ Pumps – RS-232 Interface Vulnerability</title>
      <link>https://vulnogram.org/CVE-2022-43557</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-43557</guid>
      <description>The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic…</description>
      <category>Medium</category>
      <pubDate>Mon, 05 Dec 2022 00:00:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-40263 · 6.6 MEDIUM — BD Totalys MultiProcessor - Hardcoded Credentials</title>
      <link>https://vulnogram.org/CVE-2022-40263</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-40263</guid>
      <description>BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health…</description>
      <category>Medium</category>
      <pubDate>Fri, 04 Nov 2022 18:58:53 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-30277 · 5.7 MEDIUM — BD Synapsys™ – Insufficient Session Expiration</title>
      <link>https://vulnogram.org/CVE-2022-30277</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-30277</guid>
      <description>BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (e…</description>
      <category>Medium</category>
      <pubDate>Wed, 01 Jun 2022 16:38:50 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-22767 · 8.8 HIGH — BD Pyxis™ Products – Default Credentials</title>
      <link>https://vulnogram.org/CVE-2022-22767</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-22767</guid>
      <description>Specific BD Pyxis™ products were installed with default credentials and may presently still operate with these credentials. There may be scenarios where BD Pyxis™ products are installed with the same default local operating system credentials or doma…</description>
      <category>High</category>
      <pubDate>Wed, 01 Jun 2022 16:35:38 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-22765 · 8 HIGH — BD Viper LT System - Hardcoded Credentials</title>
      <link>https://vulnogram.org/CVE-2022-22765</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-22765</guid>
      <description>BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health informat…</description>
      <category>High</category>
      <pubDate>Sat, 12 Feb 2022 02:30:40 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-22766 · 7 HIGH — BD Pyxis Products - Hardcoded Credentials</title>
      <link>https://vulnogram.org/CVE-2022-22766</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-22766</guid>
      <description>Hardcoded credentials are used in specific BD Pyxis products. If exploited, threat actors may be able to gain access to the underlying file system and could potentially exploit application files for information that could be used to decrypt applicati…</description>
      <category>High</category>
      <pubDate>Fri, 11 Feb 2022 18:12:07 GMT</pubDate>
    </item>
  </channel>