<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="rss.xsl"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Dutch Institute for Vulnerability Disclosure (DIVD) — recent CVEs</title>
    <link>https://vulnogram.org/</link>
    <atom:link href="https://vulnogram.org/rss/divd" rel="self" type="application/rss+xml"/>
    <description>Most recent CVEs assigned by Dutch Institute for Vulnerability Disclosure (DIVD) (divd).</description>
    <image>
      <url>https://vulnogram.org/seaview/icons/divd.png</url>
      <title>Dutch Institute for Vulnerability Disclosure (DIVD) — recent CVEs</title>
      <link>https://vulnogram.org/</link>
    </image>
    <lastBuildDate>Wed, 21 Oct 2026 07:00:07 GMT</lastBuildDate>
    <item>
      <title>CVE-2026-102490 · 9.4 CRITICAL 💥 🌩️ — Local privilege escalation in Zammad v1.5.0 to v7.2.2 installed via DEB or RPM package</title>
      <link>https://vulnogram.org/CVE-2026-102490</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-102490</guid>
      <description>Zammad packages built with packager.io (DEB and RPM) could have allowed a local attacker who already had file system write privileges as the unprivileged zammad service account to escalate to full root privileges on the host. Service processes began…</description>
      <category>Critical</category>
      <category>Known Exploited</category>
      <category>Network Exploitable</category>
      <pubDate>Wed, 30 Sep 2026 16:21:20 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-102489 · 9.4 CRITICAL 💥 🌩️ 👻 — Undisclosed RCE in Zammad v6.3 and higher</title>
      <link>https://vulnogram.org/CVE-2026-102489</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-102489</guid>
      <description>Zammad versions 6.3.0 to 6.5.4 are vulnerable a session hijack vulnerability that leads to remote code execution as the zammad user. The bug is also present in version 7.0.0 to version 7.1.2, but not exploitable due to changes in the underlying frame…</description>
      <category>Critical</category>
      <category>Known Exploited</category>
      <category>Network Exploitable</category>
      <category>Unsupported When Assigned</category>
      <pubDate>Wed, 30 Sep 2026 16:21:19 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22094 · 9.3 CRITICAL 🌩️ — Weak root password in EVbee DC 80</title>
      <link>https://vulnogram.org/CVE-2026-22094</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22094</guid>
      <description>The firmware for the EVbee DC-80 has a weak hardcoded root password, which allows attackers to login as root using the SSH daemon that is exposed to the network.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Tue, 29 Sep 2026 14:31:33 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22101 · 5.1 MEDIUM — Sensitive information leak through hidden menu</title>
      <link>https://vulnogram.org/CVE-2026-22101</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22101</guid>
      <description>The access to the service menu is obfuscated, but possible with only physical access. This menu exposes sensitive information such as serial numbers, MAC addresses, and WiFi network and password.</description>
      <category>Medium</category>
      <pubDate>Tue, 29 Sep 2026 14:31:28 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22104 · 7.1 HIGH — Improper access control in Hashtopolis server chunk activity component</title>
      <link>https://vulnogram.org/CVE-2026-22104</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22104</guid>
      <description>Improper access control in Hashtopolis server web-interface chunk activity component for versions prior to 0.14.8 allows any created account to read all cracked hashes of a Hashtopolis server instance.</description>
      <category>High</category>
      <pubDate>Fri, 17 Jul 2026 09:30:36 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22103 · 9.3 CRITICAL 🌩️ — Command injection in NPC start web endpoint</title>
      <link>https://vulnogram.org/CVE-2026-22103</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22103</guid>
      <description>The NPC start endpoint on the web server at port 8090 is vulnerable to command injection.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:11:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22098 · 9.2 CRITICAL 🌩️ — Sensitive information is written to logs</title>
      <link>https://vulnogram.org/CVE-2026-22098</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22098</guid>
      <description>Various sensitive information such as passwords and charging card UIDs are written to log files.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:59 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22097 · 9.3 CRITICAL 🌩️ — Missing firmware validation allows remote code execution</title>
      <link>https://vulnogram.org/CVE-2026-22097</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22097</guid>
      <description>The firmware update mechanism does not include cryptographic signature validation. This allows anyone with access to the firmware update capability to upload arbitrary files which can then lead to arbitrary code execution.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:59 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22099 · 8.7 HIGH — Missing authentication for Bluetooth communication</title>
      <link>https://vulnogram.org/CVE-2026-22099</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22099</guid>
      <description>The charging station does not require authentication for Bluetooth commands to perform actions. The functionality exposed includes sensitive information leakage, triggering reboots, or pushing a firmware update URL.</description>
      <category>High</category>
      <pubDate>Mon, 13 Jul 2026 09:10:58 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22102 · 9.3 CRITICAL 🌩️ — Arbitrary file overwrite through certificate update functionality</title>
      <link>https://vulnogram.org/CVE-2026-22102</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22102</guid>
      <description>A POST request sent to a specific webserver endpoint can be used to write to arbitrary file locations. The endpoint accepts the filename parameter in the Content-Disposition header without verification. This can be used to cause a denial of service b…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:58 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22096 · 9.3 CRITICAL 🌩️ — Missing authentication for webserver endpoints</title>
      <link>https://vulnogram.org/CVE-2026-22096</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22096</guid>
      <description>The webserver running on port 8090 does not require authentication. This allows for sensitive information leakage such as configured passwords, or uploading files through different endpoints.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:57 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22100 · 8.6 HIGH — Comnand injection in OCPP ReserveLogin message</title>
      <link>https://vulnogram.org/CVE-2026-22100</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22100</guid>
      <description>The OCPP DataTransfer message `ReserveLogin` is vulnerable to command injection. By manipulating the data value, arbitrary OS commands can be executed as root.</description>
      <category>High</category>
      <pubDate>Mon, 13 Jul 2026 09:10:57 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22095 · 9.3 CRITICAL 🌩️ — Command injection in diagnosis web endpoint</title>
      <link>https://vulnogram.org/CVE-2026-22095</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22095</guid>
      <description>The network diagnosis endpoint on the web server at port 8090 is vulnerable to command injection.</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:56 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2026-22093 · 9.5 CRITICAL 🌩️ — Adversary-in-the-Middle (AitM) attack  vulnerability in EVbee Service app</title>
      <link>https://vulnogram.org/CVE-2026-22093</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2026-22093</guid>
      <description>The EVbee Service Android app uses TLS encrypted communication (HTTPS), but does not validate the certificate provided by the server. This allows an attacker on the network path between the app and EVbee server to intercept and manipulate the communi…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 13 Jul 2026 09:10:56 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36747 · 9.4 CRITICAL 🌩️ — Hardcoded FTP Credentials within the firmware</title>
      <link>https://vulnogram.org/CVE-2025-36747</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36747</guid>
      <description>ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Sat, 13 Dec 2025 08:16:25 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36752 · 9.4 CRITICAL — Undocumented backup Account and No Password Configuration Capability</title>
      <link>https://vulnogram.org/CVE-2025-36752</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36752</guid>
      <description>Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level access to the device, such as allowing any attacker to access the Setting Center. This means that this is effectiv…</description>
      <category>Critical</category>
      <pubDate>Sat, 13 Dec 2025 08:16:25 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36754 · 9.3 CRITICAL — Authentication bypass on web interface</title>
      <link>https://vulnogram.org/CVE-2025-36754</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36754</guid>
      <description>The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an att…</description>
      <category>Critical</category>
      <pubDate>Sat, 13 Dec 2025 08:16:24 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36748 · 8.4 HIGH — Stored Cross-Site Scripting (XSS) vulnerability in Growatt ShineLan-X</title>
      <link>https://vulnogram.org/CVE-2025-36748</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36748</guid>
      <description>ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the local configuration web server. The JavaScript code snippet can be inserted in the communication module’s settings center. This may allow attackers to force a legitimate use…</description>
      <category>High</category>
      <pubDate>Sat, 13 Dec 2025 08:16:23 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36750 · 8.5 HIGH — Stored cross site scripting (XSS) vulnerability in Growatt ShineLan-X</title>
      <link>https://vulnogram.org/CVE-2025-36750</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36750</guid>
      <description>ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the Plant Name field. A HTML payload will be displayed on the plant management page via a direct post. This may allow attackers to force a legitimate user’s browser’s JavaScript…</description>
      <category>High</category>
      <pubDate>Sat, 13 Dec 2025 08:16:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36753 · 8.6 HIGH — SWD Interface Open on Growatt ShineLan-X</title>
      <link>https://vulnogram.org/CVE-2025-36753</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36753</guid>
      <description>The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device</description>
      <category>High</category>
      <pubDate>Sat, 13 Dec 2025 08:16:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36751 · 9.4 CRITICAL — Missing encryption on Local Configuration Interface or Cloud Endpoint Communication - Growatt MIC3300TL-X and ShineLan-X</title>
      <link>https://vulnogram.org/CVE-2025-36751</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36751</guid>
      <description>Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoin…</description>
      <category>Critical</category>
      <pubDate>Sat, 13 Dec 2025 08:16:21 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36746 · 4.8 MEDIUM ☁️ — SolarEdge Monitoring Platform contains a XSS upon report deletion</title>
      <link>https://vulnogram.org/CVE-2025-36746</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36746</guid>
      <description>SolarEdge monitoring platform contains a Cross‑Site Scripting (XSS) flaw that allows an authenticated user to inject payloads into report names, which may execute in a victim’s browser during a deletion attempt.</description>
      <category>Medium</category>
      <category>Cloud Hosted</category>
      <pubDate>Fri, 12 Dec 2025 15:05:40 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36743 · 8.6 HIGH — SolarEdge SE3680H - Exposed Debug interface</title>
      <link>https://vulnogram.org/CVE-2025-36743</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36743</guid>
      <description>SolarEdge SE3680H has an exposed debug/test interface accessible to unauthenticated actors, allowing disclosure of system internals and execution of debug commands.</description>
      <category>High</category>
      <pubDate>Fri, 12 Dec 2025 15:05:39 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36744 · 2.4 LOW — SolarEdge SE3680H - Information Exposure during Bootloader Loop</title>
      <link>https://vulnogram.org/CVE-2025-36744</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36744</guid>
      <description>SolarEdge SE3680H has unauthenticated disclosure of sensitive information during the bootloader loop. While the device repeatedly initializes and waits for boot instructions, the bootloader emits diagnostic output this behavior can leak operating sys…</description>
      <category>Low</category>
      <pubDate>Fri, 12 Dec 2025 15:05:39 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36745 · 8.6 HIGH — SolarEdge SE3680H contains Linux Kernel vulnerabilities</title>
      <link>https://vulnogram.org/CVE-2025-36745</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36745</guid>
      <description>SolarEdge SE3680H ships with an outdated Linux kernel containing unpatched vulnerabilities in core subsystems. An attacker with network or local access can exploit these flaws to achieve remote code execution, privilege escalation, or disclosure of s…</description>
      <category>High</category>
      <pubDate>Fri, 12 Dec 2025 15:05:38 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36755 · 2.4 LOW — CleverDisplay BlueOne unauthorized BIOS access through physical USB keyboard</title>
      <link>https://vulnogram.org/CVE-2025-36755</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36755</guid>
      <description>The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible…</description>
      <category>Low</category>
      <pubDate>Fri, 12 Dec 2025 14:58:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36759 · 8.7 HIGH 🌩️ ☁️ — Sensitive Information Disclosure in SolaX Cloud</title>
      <link>https://vulnogram.org/CVE-2025-36759</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36759</guid>
      <description>Through the provision of user names, SolaX Cloud will suggest (similar) user accounts and thereby leak sensitive information such as user email addresses and phone numbers.</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <category>Cloud Hosted</category>
      <pubDate>Wed, 10 Sep 2025 08:50:56 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36757 · 6.3 MEDIUM 🌩️ ☁️ — Bypass of administrator login screen in SolaX Cloud</title>
      <link>https://vulnogram.org/CVE-2025-36757</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36757</guid>
      <description>It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screen and gain limited access to the system.</description>
      <category>Medium</category>
      <category>Network Exploitable</category>
      <category>Cloud Hosted</category>
      <pubDate>Wed, 10 Sep 2025 08:50:55 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36758 · 6.3 MEDIUM 🌩️ ☁️ — Bypass of bruteforce protection in SolaX Cloud</title>
      <link>https://vulnogram.org/CVE-2025-36758</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36758</guid>
      <description>It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the &apos;Forgot Password&apos; functionality as an oracle.</description>
      <category>Medium</category>
      <category>Network Exploitable</category>
      <category>Cloud Hosted</category>
      <pubDate>Wed, 10 Sep 2025 08:50:54 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-36756 · 5.8 MEDIUM ☁️ — Device Takeover vulnerability in SolaX Cloud</title>
      <link>https://vulnogram.org/CVE-2025-36756</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-36756</guid>
      <description>A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known.</description>
      <category>Medium</category>
      <category>Cloud Hosted</category>
      <pubDate>Wed, 10 Sep 2025 08:50:53 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-29757 · 9.4 CRITICAL ☁️</title>
      <link>https://vulnogram.org/CVE-2025-29757</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-29757</guid>
      <description>An incorrect authorisation check in the the &apos;plant transfer&apos; function of the Growatt cloud service allowed a malicous attacker with a valid account to transfer any plant into his/her account.</description>
      <category>Critical</category>
      <category>Cloud Hosted</category>
      <pubDate>Sat, 19 Jul 2025 05:15:36 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-29756 · 8.3 HIGH ☁️ — MQTT implementation in Sungrow iSolarCloud allowed users to subscribe to all data of all connected inverters</title>
      <link>https://vulnogram.org/CVE-2025-29756</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-29756</guid>
      <description>SunGrow&apos;s back end users system iSolarCloud https://isolarcloud.com uses an MQTT service to transport data from the user&apos;s connected devices to the user&apos;s web browser. The MQTT server however did not have sufficient restrictions in place to limit the…</description>
      <category>High</category>
      <category>Cloud Hosted</category>
      <pubDate>Wed, 11 Jun 2025 08:01:16 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22371 · 9.3 CRITICAL 🌩️ — SQL-injection in admin_login_handler allows unauthenticated user to log in as an administrator in SicommNet BASEC</title>
      <link>https://vulnogram.org/CVE-2025-22371</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22371</guid>
      <description>Improper Neutralization of Special Elements used in an SQL Command (&apos;SQL Injection&apos;) vulnerability in SicommNet BASEC (SaaS Service) login page allows an unauthenticated remote attacker to Bypass Authentication and execute arbitrary SQL commands.This…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 14 Apr 2025 15:32:49 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22373 · 8.7 HIGH 🌩️ — XSS, HTML and Style injection on login page</title>
      <link>https://vulnogram.org/CVE-2025-22373</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22373</guid>
      <description>Improper Neutralization of Input During Web Page Generation (XSS or &apos;Cross-site Scripting&apos;) vulnerability in SicommNet BASEC on SaaS allows Reflected XSS, XSS Through HTTP Query Strings, Rendering of Arbitrary HTML and alternation of CSS Styles This…</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 14 Apr 2025 15:32:49 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22372 · 9.3 CRITICAL 🌩️ — Insecure password storage in SicommNet BASEC</title>
      <link>https://vulnogram.org/CVE-2025-22372</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22372</guid>
      <description>Insufficiently Protected Credentials vulnerability in SicommNet BASEC on SaaS allows Password Recovery. Passwords are either stored in plain text using reversible encryption, allowing an attacker with sufficient privileges to extract plain text passw…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Mon, 14 Apr 2025 15:32:49 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22374 · 6 MEDIUM — SSRF in CyberAudit-Web videx-legacy-ssl</title>
      <link>https://vulnogram.org/CVE-2025-22374</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22374</guid>
      <description>A Server-Side Request Forgery (SSRF) vulnerability was discovered in the videx-legacy-ssl web service of Videx’s CyberAudit-Web, affecting versions prior to 1.1.3. This vulnerability has been patched in versions after 1.1.3. Leaving this vulnerabilit…</description>
      <category>Medium</category>
      <pubDate>Thu, 10 Apr 2025 11:02:47 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22375 · 9.3 CRITICAL 🌩️ — Authentication Bypass in CyberAudit-Web</title>
      <link>https://vulnogram.org/CVE-2025-22375</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22375</guid>
      <description>An authentication bypass vulnerability was found in Videx&apos;s CyberAudit-Web. Through the exploitation of a logic flaw, an attacker could create a valid session without any credentials. This vulnerability has been patched in versions later than 9.5 and…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 10 Apr 2025 11:02:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22369 · 7.1 HIGH — Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint</title>
      <link>https://vulnogram.org/CVE-2025-22369</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22369</guid>
      <description>The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.</description>
      <category>High</category>
      <pubDate>Tue, 11 Mar 2025 13:40:24 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22366 · 8.7 HIGH — Mennekes smart/premium charges systems, Command injection in firmware upgrade</title>
      <link>https://vulnogram.org/CVE-2025-22366</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22366</guid>
      <description>The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.</description>
      <category>High</category>
      <pubDate>Tue, 11 Mar 2025 13:40:23 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22370 · 5.3 MEDIUM — Mennekes smart/premium charges systems, SQL Injection in web configuration interface</title>
      <link>https://vulnogram.org/CVE-2025-22370</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22370</guid>
      <description>Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.</description>
      <category>Medium</category>
      <pubDate>Tue, 11 Mar 2025 13:40:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22368 · 8.7 HIGH — Mennekes smart/premium charges systems, Command injection in sCU firmware update</title>
      <link>https://vulnogram.org/CVE-2025-22368</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22368</guid>
      <description>The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.</description>
      <category>High</category>
      <pubDate>Tue, 11 Mar 2025 13:40:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-22367 · 8.7 HIGH — Mennekes smart/premium charges systems, Command injection in time setting</title>
      <link>https://vulnogram.org/CVE-2025-22367</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-22367</guid>
      <description>The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.</description>
      <category>High</category>
      <pubDate>Tue, 11 Mar 2025 13:40:21 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43651 · 9.3 CRITICAL — Authenticated command injection in the &lt;redacted&gt; action leads to full remote code execution as root on the charging station</title>
      <link>https://vulnogram.org/CVE-2024-43651</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43651</guid>
      <description>Improper Neutralization of Special Elements used in a Command (&apos;Command Injection&apos;) vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The &lt;redacted&gt; b…</description>
      <category>Critical</category>
      <pubDate>Thu, 09 Jan 2025 07:56:47 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43658 · 7.2 HIGH — Using the &lt;redacted&gt; action or &lt;redacted&gt;.sh script, arbitrary files and directories can be deleted using directory traversal.</title>
      <link>https://vulnogram.org/CVE-2024-43658</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43658</guid>
      <description>Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authenticati…</description>
      <category>High</category>
      <pubDate>Thu, 09 Jan 2025 07:56:47 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43654 · 9.3 CRITICAL — Authenticated command injection in the &lt;redacted&gt; action leads to full remote code execution as root on the charging station</title>
      <link>https://vulnogram.org/CVE-2024-43654</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43654</guid>
      <description>Improper Neutralization of Special Elements used in a Command (&apos;Command Injection&apos;) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version befo…</description>
      <category>Critical</category>
      <pubDate>Thu, 09 Jan 2025 07:56:47 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43649 · 9.3 CRITICAL — Authenticated command injection via &lt;redacted&gt;.exe &lt;redacted&gt; parameter</title>
      <link>https://vulnogram.org/CVE-2024-43649</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43649</guid>
      <description>Authenticated command injection in the filename of a &lt;redacted&gt;.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a comm…</description>
      <category>Critical</category>
      <pubDate>Thu, 09 Jan 2025 07:56:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43660 · 7.5 HIGH 🌩️ — Arbitrary file download using &lt;redacted&gt;.sh</title>
      <link>https://vulnogram.org/CVE-2024-43660</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43660</guid>
      <description>The CGI script &lt;redacted&gt;.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used…</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 09 Jan 2025 07:56:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43653 · 9.3 CRITICAL — Authenticated command injection in the &lt;redacted&gt; action leads to full remote code execution as root on the charging station</title>
      <link>https://vulnogram.org/CVE-2024-43653</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43653</guid>
      <description>Improper Neutralization of Special Elements used in a Command (&apos;Command Injection&apos;) vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The &lt;red…</description>
      <category>Critical</category>
      <pubDate>Thu, 09 Jan 2025 07:56:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43661 · 9.8 CRITICAL 🌩️ — Buffer overflow in &lt;redacted&gt;.so leads to DoS of OCPP service</title>
      <link>https://vulnogram.org/CVE-2024-43661</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43661</guid>
      <description>The &lt;redacted&gt;.so library, which is used by &lt;redacted&gt;, is vulnerable to a buffer overflow in the code that handles the deletion of certificates. This buffer overflow can be triggered by providing a long file path to the &lt;redacted&gt; action of the &lt;red…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 09 Jan 2025 07:56:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2024-43652 · 9.3 CRITICAL — Authenticated command injection in the &lt;redacted&gt; action leads to full remote code execution as root on the charging station</title>
      <link>https://vulnogram.org/CVE-2024-43652</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2024-43652</guid>
      <description>Improper Neutralization of Special Elements used in a Command (&apos;Command Injection&apos;) vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The &lt;reda…</description>
      <category>Critical</category>
      <pubDate>Thu, 09 Jan 2025 07:56:46 GMT</pubDate>
    </item>
  </channel>
</rss>
