    <item>
      <title>CVE-2025-4397 · 6.8 MEDIUM — Medtronic MyCareLink Patient Monitor Data Encryption Weakness</title>
      <link>https://vulnogram.org/CVE-2025-4397</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-4397</guid>
      <description>Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.</description>
      <category>Medium</category>
      <pubDate>Thu, 07 May 2026 15:03:35 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-4386 · 6.8 MEDIUM — Medtronic MyCareLink Patient Monitor Hardware Debug Port</title>
      <link>https://vulnogram.org/CVE-2025-4386</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-4386</guid>
      <description>Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​</description>
      <category>Medium</category>
      <pubDate>Thu, 07 May 2026 15:00:21 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-12997 · 2.2 LOW</title>
      <link>https://vulnogram.org/CVE-2025-12997</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-12997</guid>
      <description>Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user informa…</description>
      <category>Low</category>
      <pubDate>Thu, 04 Dec 2025 20:04:26 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-12996 · 4.1 MEDIUM</title>
      <link>https://vulnogram.org/CVE-2025-12996</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-12996</guid>
      <description>Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.</description>
      <category>Medium</category>
      <pubDate>Thu, 04 Dec 2025 20:04:02 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-12995 · 8.1 HIGH 🌩️</title>
      <link>https://vulnogram.org/CVE-2025-12995</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-12995</guid>
      <description>Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December…</description>
      <category>High</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 04 Dec 2025 20:03:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-12994 · 5.3 MEDIUM 🌩️</title>
      <link>https://vulnogram.org/CVE-2025-12994</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-12994</guid>
      <description>Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.</description>
      <category>Medium</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 04 Dec 2025 20:02:06 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-4395 · 6.8 MEDIUM — Medtronic MyCareLink Patient Monitor Empty Password Vulnerability</title>
      <link>https://vulnogram.org/CVE-2025-4395</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-4395</guid>
      <description>Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor mo…</description>
      <category>Medium</category>
      <pubDate>Thu, 24 Jul 2025 03:30:24 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-4394 · 6.8 MEDIUM — Medtronic MyCareLink Patient Monitor Unencrypted Filesystem Vulnerability</title>
      <link>https://vulnogram.org/CVE-2025-4394</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-4394</guid>
      <description>Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 202…</description>
      <category>Medium</category>
      <pubDate>Thu, 24 Jul 2025 03:26:06 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-4393 · 6.5 MEDIUM — Medtronic MyCareLink Patient Monitor Deserialization Vulnerability</title>
      <link>https://vulnogram.org/CVE-2025-4393</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-4393</guid>
      <description>Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects MyCareLink Pat…</description>
      <category>Medium</category>
      <pubDate>Thu, 24 Jul 2025 03:22:20 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-31222 · 9.8 CRITICAL 🌩️ — Medtronic Paceart MSMQ Deserialization of Untrusted Data</title>
      <link>https://vulnogram.org/CVE-2023-31222</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-31222</guid>
      <description>Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic&apos;s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac devic…</description>
      <category>Critical</category>
      <category>Network Exploitable</category>
      <pubDate>Thu, 29 Jun 2023 15:19:22 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2023-25931 · 6.4 MEDIUM — Medtronic Micro Clinician &amp; InterStim X Clinician App Password Reset Issue</title>
      <link>https://vulnogram.org/CVE-2023-25931</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2023-25931</guid>
      <description>Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control…</description>
      <category>Medium</category>
      <pubDate>Wed, 01 Mar 2023 18:56:30 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2022-32537 · 4.8 MEDIUM — Medtronic MiniMed 600 Series Pump System Communication Issue</title>
      <link>https://vulnogram.org/CVE-2022-32537</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2022-32537</guid>
      <description>A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal prox…</description>
      <category>Medium</category>
      <pubDate>Thu, 17 Nov 2022 20:47:05 GMT</pubDate>
    </item>