<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="rss.xsl"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Philips — recent CVEs</title>
    <link>https://vulnogram.org/</link>
    <atom:link href="https://vulnogram.org/rss/philips" rel="self" type="application/rss+xml"/>
    <description>Most recent CVEs assigned by Philips (philips).</description>
    <image>
      <url>https://vulnogram.org/seaview/icons/philips.png</url>
      <title>Philips — recent CVEs</title>
      <link>https://vulnogram.org/</link>
    </image>
    <lastBuildDate>Wed, 21 Oct 2026 07:00:07 GMT</lastBuildDate>
    <item>
      <title>CVE-2025-3426 · 7.2 HIGH — Use of default hardcoded credentials</title>
      <link>https://vulnogram.org/CVE-2025-3426</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-3426</guid>
      <description>We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugg…</description>
      <category>High</category>
      <pubDate>Mon, 07 Apr 2025 16:23:00 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-3425 · 7.3 HIGH — Unauthenticated Remote Code Execution via .NET Deserialization</title>
      <link>https://vulnogram.org/CVE-2025-3425</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-3425</guid>
      <description>The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the serv…</description>
      <category>High</category>
      <pubDate>Mon, 07 Apr 2025 16:05:46 GMT</pubDate>
    </item>
    <item>
      <title>CVE-2025-3424 · 7.7 HIGH — 3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel</title>
      <link>https://vulnogram.org/CVE-2025-3424</link>
      <guid isPermaLink="true">https://vulnogram.org/CVE-2025-3424</guid>
      <description>The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the &quot;Object Marshalling&quot; technique, which allows an attacker to read internal files without any authe…</description>
      <category>High</category>
      <pubDate>Mon, 07 Apr 2025 15:36:46 GMT</pubDate>
    </item>